Guidance on new compliance path for ASHRAE 90.1-2016 now available

by Brianna Crandall — January 27, 2016—A newly published document from global building technology society ASHRAE and the Illuminating Engineering Society (IES) gives users of their energy efficiency standard immediate access to an optional third path for compliance, providing more flexibility for the industry.

Standard 90.1-2013 Appendix G: Performance Rating Method is an excerpt from ANS I / ASHRAE / IES Standard 90.1-2013 (I-P), Energy Standard for Buildings Except Low-Rise Residential Buildings. The document gives users immediate access to selected addenda slated to be published in the 2016 version of the standard. The majority of the document is comprised of addendum bm, which allows Appendix G to be used as a compliance path within the standard.

Drake Erbe, chair of the Standard 90.1 committee, pointed out:

This document is being provided at the request of users. This is the first time ASHRAE and IES have made available an interim clean publication of a portion of Standard 90.1, and we are doing so now because users have expressed a critical need for this guidance. Several entities have expressed interest in developing programs based on the revised appendix. This release also gives advanced notice to software developers that may be interested in automating the process of creating the Appendix G baseline.

Erbe notes that the guidance in addendum bm had two significant impacts on Appendix G:

Previously Appendix G was used only to rate ‘beyond code’ performance of buildings, but could not be used to demonstrate compliance with the base 90.1 standard. Now the standard provides that compliance path and gives credit for integrated design resulting in energy savings such as efficient use of building mass, optimized building orientation, efficient HVAC&R system selection, and right-sizing of HVAC&R equipment.

Using this new version of Appendix G to show compliance with the 2016 version of the standard, the proposed building design needs to have a Performance Cost Index (PCI) less than that shown in Table 4.2.1.1, based on building type and climate zone.

The second change is that the baseline design is now fixed at a certain level of performance, the stringency of which is expected not to change with subsequent versions of the standard. By this, a building of any era can be rated using the same method with the same baseline of compliance. The intent is that any building energy code or beyond-code program can use this methodology and simply set the appropriate target for their needs analogous to those in the table.

Therefore, a beyond-code program may wish to set a target less than is shown in the table (a target of 0 is a net zero building), while compliance with a previous version of the standard may wish to set a target above what is shown. Because unregulated loads are not included in the compliance target in Table 4.2.1.1, beyond-code programs that encourage improvement in unregulated loads may wish to modify the target to include those loads.

Other addenda included in the excerpt are:

  • Addendum k directs the modeler to use the default assemblies in Appendix A for baseline opaque envelope assemblies.
  • Addendum r establishes the hierarchy of the decision-making process for selecting baseline HVAC systems.
  • Addendum z provides detail on the simulation of base-line building heat pumps, including how auxiliary heat is used in conjunction with heat-pump heating.
  • Addendum aa provides direction regarding when it is appropriate to model a heating-only system in Appendix G.
  • Addendum ad clarifies when baseline HVAC systems should be modeled with preheat coils.
  •  Addendum dx makes changes to the baseline lighting power allowances in Appendix G.

Erbe noted that while it is likely that the version of Appendix G published in the 2016 edition of the standard will include additional changes to Appendix G, it is not likely that they will be as extensive as those included in addendum bm. The primary focus is to make the new methodology with a fixed baseline available so users become familiar with it.

The cost of Standard 90.1-2013 Appendix G: Performance Rating Method — Excerpt from ANSI / ASHRAE / IES Standard 90.1-2013 (I-P), available from the ASHRAE Bookstore, is $41 ($35 for ASHRAE members).